5.4 Installation of Cable Drum
5.4.1 The installation of cable drum shall be in compliance with the following requirements(Figure 5.4.1):
1 The levelness of the drum is adjusted,and allowable deviation shall be 1/1000 of the length of drum;
2 The lateral deviation of the drum on the datum line of the rail is adjusted and is detected at W1 and W2,and allowable deviation shall be 1.0mm.
![img](https://epubservercos.yuewen.com/89A973/18000637808217506/epubprivate/OEBPS/Images/txt005_2.jpg?sign=1734426275-oLdrT0S9lPfp5ZV2c3ECMCSWFQBdK94i-0-a4c27d46f0d1a9cd2baf8243bd558412)
Figure 5.4.1 Detection figure of cable drum
1-Level gauge;2-Drum;3-Traveling rail;4-Plumb bob
5.4.2 The installation of reel shall be in compliance with the following requirements:
1 The lateral deviation of the reel and the longitudinal datum line of drum is adjusted,and allowable deviation shall be 5.0mm.
2 The perpendicularity of the reel is adjusted,and allowable deviation shall be 2.0mm.